[Header]	
Customer Name	ILLUMINA, INC.
Product Type	15033972
Date Manufactured	11/06/2013
Lot	WO0000109373380
DesignStudio ID	29247
Target Plexity	105
	
[Probes]
Gene Name	Transcript ID	Assay ID	Left Exon	Right Exon	Species	Build ID	Chromosome	Start Position	End Position	ULSO Sequence	ULSO Genomic Hits	DLSO Sequence	DLSO Genomic Hits	Probe Strand	Designer	Design Score	SNP Masking	Labels
AKT1	NM_001014432	6694989	4	3	Homo sapiens	hg19	chr14	105246457	105243085	GTGAGGCTCCCCTCAACAACTTCTCT	1	GTGCCAGCTGATGAAGACGGAG	9	MINUS	ILLUMINA	1.38	false	FromReportXYZ;FromStudyXYZ
ATF1	NM_005171	6832570	2	3	Homo sapiens	hg19	chr12	51189762	51203282	ACGGGATCCTAGCACGGCGCCCATCTTA	1	TTCTGAAGATACACGGGGCAGAA	3	PLUS	ILLUMINA	1.411	false	FromStudyXYZ
BCL10	NM_003921	6712588	1	0	Homo sapiens	hg19	chr1	85742004	85736561	AGGACCTCACTGAAGTGAAGAAGGA	1	GCCTTAGAAAATTTACGTGTATACCTGTG	1	MINUS	ILLUMINA	1.771	false	
BCL2L1	NM_138578	6790061	1	0	Homo sapiens	hg19	chr20	30310459	30310120	GGCTGCACCTGCCTGCCTTTGCCTAA	1	TTTCTCTCCCTTCAGAATCTTATCTTGGC	1	MINUS	ILLUMINA	1.687	false	
BCL3	NM_005178	6793284	1	2	Homo sapiens	hg19	chr19	45254610	45259517	CCACCCGTGCAGATGAGGACGGAGACA	1	CTCCATATTGCTGTGGTGCAGGGTA	1	PLUS	ILLUMINA	1.659	false	
BIRC2	NM_001166	6703614	3	4	Homo sapiens	hg19	chr11	102233673	102234426	ATTCAAGGTAGATATCCTCATCTTCTTG	1	TGTTGTCAACTTCAGATACCACTGGAG	1	PLUS	ILLUMINA	1.938	false	
BIRC3	NM_182962	6764041	5	6	Homo sapiens	hg19	chr11	102199642	102201757	AGACAGCCCAGGAGATGAAAATGCA	2	TATCCATTTTGAACCTGGAGAAGACCA	1	PLUS	ILLUMINA	1.881	false	
C3	NM_000064	6629153	1	0	Homo sapiens	hg19	chr19	6720563	6719382	TACTAACCCACCTCCCCCTGGCTCT	2	TCACCCCCAACATCTTGCGGCT	3	MINUS	ILLUMINA	1.241	false	
CARD11	NM_032415	6647989	10	9	Homo sapiens	hg19	chr7	2974117	2972179	CCAGCGCAGGATGAACCTGAAG	3	TCCCCCATCAGCCTGAAGCGAACATCA	1	MINUS	ILLUMINA	1.35	false	
CASP1	NM_033292	6735042	9	8	Homo sapiens	hg19	chr11	104896981	104896300	AAGGAAACTGTATGAATGTCTGTGGGC	4	AAGTGAAGAGATCCTTCTGTAAAGGTT	1	MINUS	ILLUMINA	1.98	false	
CASP8	NM_033355	6847575	3	4	Homo sapiens	hg19	chr2	202136310	202137388	AGGAAATCTCCAAATGCAAACTGGATG	1	ACCTGCTGGATATTTTCATAGAGATGG	1	PLUS	ILLUMINA	1.994	false	
CCL11	NM_002986	6804658	1	2	Homo sapiens	hg19	chr17	32614196	32614631	CCAGTGGCAAATGTCCCCAGAAA	9	TTCAAGACCAAACTGGCCAAGGATATC	2	PLUS	ILLUMINA	1.62	false	
CCL2	NM_002982	6719302	1	2	Homo sapiens	hg19	chr17	32583329	32583769	CAGCAGCAAGTGTCCCAAAGAAG	7	GACCATTGTGGCCAAGGAGATCT	7	PLUS	ILLUMINA	1.243	false	
CCL22	NM_002990	6796839	0	1	Homo sapiens	hg19	chr16	57392775	57394392	CTGTGGCGCTTCAAGCAACTGA	7	GGAAGACAGCGTCTGCTGCCGTGAT	1	PLUS	ILLUMINA	1.249	false	
CCL5	NM_002985	6775348	1	0	Homo sapiens	hg19	chr17	34207270	34205615	GCTACTGCCCTCTGCGCTCCTGCATCT	1	CCTCGGACACCACACCCTGCTGCTTT	1	MINUS	ILLUMINA	1.59	false	
CCR5	NM_001100168	6792447	1	2	Homo sapiens	hg19	chr3	46412449	46414420	ACATCCGTTCCCCTACAAGAAACTCT	1	AGATGGATTATCAAGTGTCAAGTCCAATC	1	PLUS	ILLUMINA	1.854	false	
CD27	NM_001242	6816931	0	1	Homo sapiens	hg19	chr12	6554369	6554627	AAAGCTGTGCTGCCAGATGTGTGA	3	GAAGGACTGTGACCAGCATAGAAAG	1	PLUS	ILLUMINA	1.645	false	
CD40	NM_001250	6615876	1	2	Homo sapiens	hg19	chr20	44750507	44750899	AACAGTCAGTGCTGTTCTTTGTGCCA	1	AGAAACTGGTGAGTGACTGCACAGA	1	PLUS	ILLUMINA	1.845	false	
CD69	NM_001781	6793836	4	3	Homo sapiens	hg19	chr12	9907219	9906148	CATGGAAGTGGTCAAATGGCAAAGA	1	GGGTCTGACAAGTGTGTTTTTCTGA	1	MINUS	ILLUMINA	1.787	false	
CD80	NM_005191	6856478	2	1	Homo sapiens	hg19	chr3	119276501	119263686	GGCTGGTCTTTCTCACTTCTGTTCA	2	TATCCACGTGACCAAGGAAGTGAAA	1	MINUS	ILLUMINA	1.78	false	
CD83	NM_004233	6670785	2	3	Homo sapiens	hg19	chr6	14131949	14133922	CTAAGTGGCAAGGTGATCTTGAGAGTG	2	GCGTAAAGAAGAGACTTTTAAGAAATACAG	1	PLUS	ILLUMINA	1.734	false	
CDKN1A	NM_078467	6677447	2	3	Homo sapiens	hg19	chr6	36652287	36653560	TCTCAGGGTCGAAAACGGCGGCAGA	1	TCCAAACGCCGGCTGATCTTCT	1	PLUS	ILLUMINA	1.238	false	
CFLAR	NM_003879	6709279	3	4	Homo sapiens	hg19	chr2	202000796	202005108	CCTGAAGACAAAAATCCAGAAGTACAAGC	1	AAGGAGCAGGGACAAGTTACAGGAAT	1	PLUS	ILLUMINA	1.861	false	
CHUK	NM_001278	6652539	20	19	Homo sapiens	hg19	chr10	101950658	101949347	GAGGCAAATGAGGAACAGGGCAATA	1	GAGTTGGTTAACAGAATGAGTTGTCAC	1	MINUS	ILLUMINA	1.881	false	
CSF1	NM_172212	6781994	3	4	Homo sapiens	hg19	chr1	110460051	110464495	GCTGCTTCACCAAGGATTATGAAGAG	1	CCTGCGTCCGAACTTTCTATGAGACA	1	PLUS	ILLUMINA	1.919	false	
CSF2	NM_000758	6861498	0	1	Homo sapiens	hg19	chr5	131409641	131409807	TCCTGAACCTGAGTAGAGACACTGCT	1	AACAGTAGAAGTCATCTCAGAAATGTTTG	1	PLUS	ILLUMINA	1.819	false	
CSF3	NM_172219	6783074	0	1	Homo sapiens	hg19	chr17	38171738	38171969	CTGCCACCCAGAGCCCCATGAAGCTGAT	1	CCCTGCAGCTGCTGCTGTGGCACAGT	2	PLUS	ILLUMINA	1.514	false	
CXCL1	NM_001511	6624703	2	3	Homo sapiens	hg19	chr4	74735674	74736263	AGTTAAGAAAATCATCGAAAAGATGCTG	3	GACAAATCCAACTGACCAGAAGGGA	2	PLUS	ILLUMINA	1.808	false	
CXCL10	NM_001565	6807489	1	0	Homo sapiens	hg19	chr4	76944558	76943932	CTGCCTTATCTTTCTGACTCTAAGTGGC	1	GAACTGTACGCTGTACCTGCATCA	1	MINUS	ILLUMINA	1.732	false	
CXCL2	NM_002089	6673109	3	2	Homo sapiens	hg19	chr4	74964350	74963448	GGTTAAGAAAATCATCGAAAAGATGCTG	3	ACCAGAAGGAAGGAGGAAGCTTATTG	2	MINUS	ILLUMINA	1.917	false	
CXCL9	NM_002416	6724096	1	0	Homo sapiens	hg19	chr4	76928567	76927403	CATCTTGCTGGTTCTGATTGGAGTG	1	AACCCCAGTAGTGAGAAAGGGTCG	2	MINUS	ILLUMINA	1.63	false	
EGFR	NM_005228	6606536	0	1	Homo sapiens	hg19	chr7	55087024	55210022	CTGCCCGGCGAGTCGGGCTCTGGAGGAAAA	1	CAAGCTCACGCAGTTGGGCACTTTT	1	PLUS	ILLUMINA	1.363	false	
EGR1	NM_001964	6618414	0	1	Homo sapiens	hg19	chr5	137801727	137802485	GGCGAGCAGCCCTACGAGCACCTGA	1	TCTCTCTGAACAACGAGAAGGTGCT	2	PLUS	ILLUMINA	1.541	false	
ELK1	NM_001114123	6755908	6	5	Homo sapiens	hg19	chrX	47496450	47496295	CCCATTGCGCCCCGTAGCCCGGCCAA	3	CCATCCAGTGGCAGCGCCCAGGTGCACAT	3	MINUS	ILLUMINA	1.179	false	
FASLG	NM_000639	6690598	2	3	Homo sapiens	hg19	chr1	172633502	172634789	GGAGCTGAGGAAAGTGGCCCATTTAA	2	CAAGTCCAACTCAAGGTCCATGCCTCT	1	PLUS	ILLUMINA	1.903	false	
FOS	NM_005252	6623033	2	3	Homo sapiens	hg19	chr14	75747338	75747514	CGGAGGAGGGAGCTGACTGATACACT	1	AGACAGACCAACTAGAAGATGAGAAGTC	1	PLUS	ILLUMINA	1.857	false	
GADD45B	NM_015675	6737962	2	3	Homo sapiens	hg19	chr19	2477222	2477510	CCGAGACCTGCATTGTCTCCTGGTCA	1	CCCTCACACGGACGCCTGGAAGA	2	PLUS	ILLUMINA	1.405	false	
HMOX1	NM_002133	6706694	2	3	Homo sapiens	hg19	chr22	35783143	35785897	AAGACTGCGTTCCTGCTCAACAT	2	AGCTGCTGACCCATGACACCAA	6	PLUS	ILLUMINA	1.111	false	
ICAM1	NM_000201	6790055	4	5	Homo sapiens	hg19	chr19	10395301	10395495	ACAAGAACCAGACCCGGGAGCTT	4	CTGGACGAGAGGGATTGTCCGGGAAA	1	PLUS	ILLUMINA	1.475	false	
IFNA1	NM_024013	6860746	0	0	Homo sapiens	hg19	chr9	21440858	21440914	GACTTGGAAGCCTGTGTGATGCA	15	AGGGTGGGAGAAACTCCCCTGATGAAT	8	PLUS	ILLUMINA	1.572	false	
IFNB1	NM_002176	6793846	0	0	Homo sapiens	hg19	chr9	21077560	21077485	TATTGTTGAGAACCTCCTGGCTAATGTC	1	GAAGACAGTCCTGGAAGAAAAACTGGAG	1	MINUS	ILLUMINA	1.94	false	
IFNG	NM_000619	6757470	1	0	Homo sapiens	hg19	chr12	68553318	68552002	ATATGTAAAAGAAGCAGAAAACCTTAAGA	1	TTCAGATGTAGCGGATAATGGAACTCT	1	MINUS	ILLUMINA	1.802	false	
IKBKE	NM_014002	6823527	0	1	Homo sapiens	hg19	chr1	206644015	206644528	GCCTGCATCCCCTGCAGTGGAGAT	2	CTCCTGGACGTGCCACAGACAGAAA	1	PLUS	ILLUMINA	1.492	false	
IKBKG	NM_003639	6701312	1	2	Homo sapiens	hg19	chrX	153780377	153784407	TGCCTGGAGGAGAATCAAGAGCT	9	CATCCGGCAGAGCAACCAGATTCT	2	PLUS	ILLUMINA	1.364	false	
IL12B	NM_002187	6841426	4	3	Homo sapiens	hg19	chr5	158749434	158747498	TGATTTGACATTCAGTGTCAAAAGCAGC	1	CCCCCAAGGGGTGACGTGCGGA	3	MINUS	ILLUMINA	1.325	false	
IL15	NM_172175	6718629	8	9	Homo sapiens	hg19	chr4	142651103	142653931	TCATCCTAGCAAACAACAGTTTGTCTTC	1	GGATGCAAAGAATGTGAGGAACTGGA	2	PLUS	ILLUMINA	1.936	false	
IL1B	NM_000576	6710123	1	0	Homo sapiens	hg19	chr2	113594317	113593778	TGGGATTCTCTTCAGCCAATCTTCA	3	GGCAGAAGTACCTGAGCTCGCCAGTGA	1	MINUS	ILLUMINA	1.75	false	
IL1R1	NM_000877	6612632	0	1	Homo sapiens	hg19	chr2	102770443	102774211	TGGACCCCTTGGTAAAAGACAAGG	2	AATATGAAAGTGTTACTCAGACTTATTTGT	1	PLUS	ILLUMINA	1.452	false	
IL1RN	NM_173843	6641824	4	5	Homo sapiens	hg19	chr2	113888702	113890258	AAGTCTGGTGATGAGACCAGACTCCA	2	CAGTTAACATCACTGACCTGAGCGA	1	PLUS	ILLUMINA	1.837	false	
IL2	NM_000586	6721451	2	1	Homo sapiens	hg19	chr4	123377331	123374975	ATGCTCACATTTAAGTTTTACATGCCC	1	AGAACTGAAACATCTTCAGTGTCTAGAAG	1	MINUS	ILLUMINA	1.872	false	
IL6	NM_000600	6820760	0	1	Homo sapiens	hg19	chr7	22766870	22767086	AGGAGCCCAGCTATGAACTCCTTCT	1	CGCCTTCGGTCCAGTTGCCTTCT	1	PLUS	ILLUMINA	1.43	false	
IL8	NM_000584	6669954	1	2	Homo sapiens	hg19	chr4	74607360	74607693	GAGAGTGGACCACACTGCGCCAACACA	1	GTAAAGCTTTCTGATGGAAGAGAGCTC	1	PLUS	ILLUMINA	1.842	false	
IRAK1	NM_001569	6728992	1	0	Homo sapiens	hg19	chrX	153285157	153285026	CCCTGGAGCCCGCCGACTGGTGCCAGTT	1	CCGCCCTGATCGTGCGCGACCAGA	1	MINUS	ILLUMINA	1.12	false	
IRAK2	NM_001570	6803734	2	3	Homo sapiens	hg19	chr3	10242169	10251297	CCTGTGAGGATGGCCACCTTTCCA	2	CCTCTCCAGCCAGAGCCCACCA	53	PLUS	ILLUMINA	1.111	false	
IRF1	NM_002198	6680986	1	0	Homo sapiens	hg19	chr5	131826261	131825135	CCGCCGAATCGCTCCTGCAGCAGA	1	CTCGGATGCGCATGAGACCCTGGCTA	1	MINUS	ILLUMINA	1.416	false	
LTBR	NM_002342	6732979	2	3	Homo sapiens	hg19	chr12	6494285	6494425	CTGCCAGCTGTGCCGCCCCTGTGA	2	TCGAGGAGATTGCCCCCTGCACAA	1	PLUS	ILLUMINA	1.24	false	
MALT1	NM_006785	6614595	15	16	Homo sapiens	hg19	chr18	56412995	56414666	CCAGACTCAGTTCACTGCAAAAA	8	AACATCTAGTCTTCACAGTATGTTTATCA	1	PLUS	ILLUMINA	1.47	false	
MAP2K6	NM_002758	6649323	0	1	Homo sapiens	hg19	chr17	67411109	67501959	TCAAAGGAAAGGGGAAAATGTCTCAGTC	2	AACCCTGGCCTTAAAATTCCAAAAGAAG	1	PLUS	ILLUMINA	1.94	false	
MAP3K1	NM_005921	6654353	1	2	Homo sapiens	hg19	chr5	56152552	56155569	AAAGGAGAAATAGGCGAGGGCCT	5	GTGGTAAAACCAATCCCAGTTAAAGGAG	1	PLUS	ILLUMINA	1.594	false	
MMP9	NM_004994	6729434	11	12	Homo sapiens	hg19	chr20	44643077	44644925	GTGCCTTTGGACACGCACGACGTCTT	1	GCCAGGACCGCTTCTACTGGCG	1	PLUS	ILLUMINA	1.255	false	
MYC	NM_002467	6670402	1	2	Homo sapiens	hg19	chr8	128751231	128752671	TGAGGAGACACCGCCCACCACCA	4	AGGAACAAGAAGATGAGGAAGAAATCG	1	PLUS	ILLUMINA	1.518	false	
MYD88	NM_002468	6654261	3	4	Homo sapiens	hg19	chr3	38182307	38182665	TCCAGACCAAATTTGCACTCAGCCT	4	CTGATCCCCATCAAGTACAAGGCAAT	2	PLUS	ILLUMINA	1.85	false	
NFKB1	NM_003998	6777413	5	6	Homo sapiens	hg19	chr4	103488264	103498066	ACTGCTGGACCCAAGGACATGGT	5	AACCTGGGTATACTTCATGTGACAAAG	1	PLUS	ILLUMINA	1.594	false	
NFKB2	NM_002502	6830412	19	20	Homo sapiens	hg19	chr10	104161248	104161530	CCACCCCTGACCCCGCCCAGCCCAGCA	4	GACTGTCACTTGGTGATACAGCT	3	PLUS	ILLUMINA	1.113	false	
NFKBIA	NM_020529	6810000	5	4	Homo sapiens	hg19	chr14	35871626	35871239	GAGTTCACGGAGTTCACAGAGGA	4	CCCTATGATGACTGTGTGTTTGGAG	2	MINUS	ILLUMINA	1.505	false	
NFKBIB	NM_002503	6858306	3	4	Homo sapiens	hg19	chr19	39397921	39398079	GAGATGCTGGAGCTGACCTTGACAAA	1	GCCCCCTTCATTTGGCAGTGGA	5	PLUS	ILLUMINA	1.407	false	
NFKBIE	NM_004556	6824750	3	2	Homo sapiens	hg19	chr6	44229395	44228252	ACTCTCTGGACCTCCAGCTGCAAAACT	1	TGGCTTGTCTCCACATTGCCAC	11	MINUS	ILLUMINA	1.419	false	
NR4A2	NM_006186	6729825	7	6	Homo sapiens	hg19	chr2	157182692	157182482	TCCTGCATTGCTGCCCTGGCTAT	8	CGGGCTCAAGGAACCCAAGAGAGT	2	MINUS	ILLUMINA	1.306	false	
PDGFB	NM_033016	6816863	4	3	Homo sapiens	hg19	chr22	39627653	39626190	ACCCAGGTGCAGCTGCGACCTGT	4	TGCGGAAGAAGCCAATCTTTAAGAA	1	MINUS	ILLUMINA	1.404	false	
PLAU	NM_002658	6845100	6	7	Homo sapiens	hg19	chr10	75673482	75673777	CCTTGCTGGGTGATCAGCGCCACACA	1	GGAGGACTACATCGTCTACCTGGGT	1	PLUS	ILLUMINA	1.638	false	
PTGS2	NM_000963	6636217	9	8	Homo sapiens	hg19	chr1	186644415	186643854	GCTGAAGCCCTATGAATCATTTGAAGA	1	CTGCAGAGTTGGAAGCACTCTATGGT	1	MINUS	ILLUMINA	1.95	false	
RAF1	NM_002880	6850068	16	15	Homo sapiens	hg19	chr3	12626376	12626113	AGTAAAGGAAGAGAGGCCTCTTTTTCC	1	TGCTCCAACACTCTCTACCGAAGAT	3	MINUS	ILLUMINA	1.885	false	
REL	NM_002908	6858151	9	10	Homo sapiens	hg19	chr2	61147743	61148939	CGGTTCAATTGGAGAAGGAAGATACTTC	1	CTCATGATGCAGTTGTGAGAGAAATGC	1	PLUS	ILLUMINA	1.971	false	
RELA	NM_001243985	6824561	3	2	Homo sapiens	hg19	chr11	65429435	65429278	TACCACCAAGACCCACCCCACCATCAA	1	GGCTACACAGGACCAGGGACAGT	7	MINUS	ILLUMINA	1.472	false	
RELB	NM_006509	6842556	1	2	Homo sapiens	hg19	chr19	45506226	45515230	ACTCTCGCTCGCCGTTTCCAGGA	1	TACATCAAGGAGAACGGCTTCGG	2	PLUS	ILLUMINA	1.183	false	
RHOA	NM_001664	6715927	2	1	Homo sapiens	hg19	chr3	49412899	49405938	TATGTGGCAGATATCGAGGTGGATGGA	2	GGACACAGCTGGGCAGGAAGATTATGA	5	MINUS	ILLUMINA	1.938	false	
RIPK1	NM_003804	6724347	0	1	Homo sapiens	hg19	chr6	3077187	3078056	ATGAAAACAGTGTACAAGGGGCCCAA	1	GGAGGCGAAGATGATGAACAGAC	7	PLUS	ILLUMINA	1.583	false	
SELE	NM_000450	6752002	13	12	Homo sapiens	hg19	chr1	169694904	169693618	AGCCTTCTTACATCCTTTAAGTTCAAAAG	1	TGCATCTGGGGAACTAGAGGGATACA	1	MINUS	ILLUMINA	1.82	false	
SELP	NM_003005	6634738	16	15	Homo sapiens	hg19	chr1	169559417	169558667	TTACAAACGCTGCATTTGACCCGAGT	1	CATAAACACCCATGAATCAAAGACATGG	1	MINUS	ILLUMINA	1.926	false	
SOD2	NM_001024465	6730823	4	3	Homo sapiens	hg19	chr6	160105918	160103645	GTCCAAATCAGGATCCACTGCAAGGAA	1	CCTTATTCCACTGCTGGGGATTGAT	1	MINUS	ILLUMINA	1.868	false	
STAT1	NM_007315	6644350	22	21	Homo sapiens	hg19	chr2	191841600	191840589	TGCCTTTGGAAAGTATTACTCCAGGC	1	ACCAGAGCCAATGGAACTTGATGG	3	MINUS	ILLUMINA	1.733	false	
STAT3	NM_213662	6751980	20	19	Homo sapiens	hg19	chr17	40475052	40474469	ACTTTCACTTGGGTGGAGAAGGACAT	1	TGGAACCATACACAAAGCAGCAG	9	MINUS	ILLUMINA	1.6	false	
STAT5B	NM_012448	6739147	18	17	Homo sapiens	hg19	chr17	40354392	40353858	TGTCCCCAGGCTCACTATAACATGTA	2	CCTGACTCAGTCCTTGACACCGAT	2	MINUS	ILLUMINA	1.713	false	
TBK1	NM_013254	6713135	19	20	Homo sapiens	hg19	chr12	64891785	64895151	AAAGAACTTGCTGAAAATAACCACATT	1	CATGGATGGTGGCCTTCGCAACGTTGA	1	PLUS	ILLUMINA	1.819	false	
TICAM1	NM_182919	6845614	1	0	Homo sapiens	hg19	chr19	4831660	4818495	GACCCAGTGGCGCAGCCGGCAG	9	TGGGCAGCTCCTGCAGAACCTGGAACA	2	MINUS	ILLUMINA	1.147	false	
TLR1	NM_003263	6764733	3	2	Homo sapiens	hg19	chr4	38802510	38800484	TAACAAAGGCATATTGGGCACCCCTA	1	ATCTGTATCAAGATGATCTGAAGAACAGC	1	MINUS	ILLUMINA	1.852	false	
TLR2	NM_003264	6843277	1	2	Homo sapiens	hg19	chr4	154609165	154624070	ATTGCTCTTTCACTGCTTTCAACTGG	1	TTGAAGCACTGGACAATGCCACATAC	1	PLUS	ILLUMINA	1.939	false	
TLR3	NM_003265	6619667	3	4	Homo sapiens	hg19	chr4	187005294	187005838	ACACCATCTATTAAAAGACCCATTATGC	1	CATGCAGTTCAACAAGCTATTGAACAA	1	PLUS	ILLUMINA	1.935	false	
TLR6	NM_006068	6648116	1	0	Homo sapiens	hg19	chr4	38858416	38831117	AAGTTATTTTCTCTTCTTCTGAAAAAGAGA	1	ATGCTCTGAAGAAGAACAACCCT	4	MINUS	ILLUMINA	1.322	false	
TLR9	NM_017442	6694397	1	0	Homo sapiens	hg19	chr3	52259579	52258291	GCCAGACCCTCTGGAGAAGCCCCT	5	CAGCGCCCTGCACCCGCTGTCTCTCCT	1	MINUS	ILLUMINA	1.256	false	
TNF	NM_000594	6633875	1	2	Homo sapiens	hg19	chr6	31544322	31544571	CCTCTCTCTAATCAGCCCTCTGGC	3	ATCATCTTCTCGAACCCCGAGTGACAA	1	PLUS	ILLUMINA	1.696	false	
TNFAIP3	NM_006290	6803532	7	8	Homo sapiens	hg19	chr6	138201357	138202194	TTTCATGAGGCCAAAAGGACAGAAGAG	1	GATCGAGCCAGCGCAGAGATGT	3	PLUS	ILLUMINA	1.455	false	
TNFRSF10A	NM_003844	6766718	3	2	Homo sapiens	hg19	chr8	23060193	23059392	TTGCTTGCCTCCCATGTACAGCTTGTA	1	CCCTGCACCACGACCAGGAACACA	3	MINUS	ILLUMINA	1.633	false	
TNFRSF10B	NM_147187	6691449	8	7	Homo sapiens	hg19	chr8	22884678	22881733	ATGTTGTCCCCCGGGGAGTCAGAGCAT	1	AAGGTCTCAGAGGAGGAGGCTGCT	7	MINUS	ILLUMINA	1.551	false	
TNFRSF1A	NM_001065	6670733	1	0	Homo sapiens	hg19	chr12	6450972	6443382	CTCCACCGTGCCTGACCTGCTG	42	TGCTCCTGGAGCTGTTGGTGGGAATATA	1	MINUS	ILLUMINA	1.335	false	
TNFRSF1B	NM_001066	6623911	2	3	Homo sapiens	hg19	chr1	12251112	12251867	TGCTTGAGCTGTGGCTCCCGCTGTA	1	AAGCCTGCACTCGGGAACAGAA	6	PLUS	ILLUMINA	1.238	false	
TNFSF10	NM_003810	6647296	4	3	Homo sapiens	hg19	chr3	172227041	172224685	GACCAGAGGAAGAAGCAACACATTGT	2	CTCCAAGAATGAAAAGGCTCTGGG	2	MINUS	ILLUMINA	1.73	false	
TNFSF14	NM_172014	6825972	4	3	Homo sapiens	hg19	chr19	6667149	6665340	GGTCAACCCAGCAGCGCATCTCACA	1	GGGCCAACTCCAGCTTGACCGG	6	MINUS	ILLUMINA	1.172	false	
TP53	NM_001126114	6709182	7	6	Homo sapiens	hg19	chr17	7577524	7577127	ACCATCATCACACTGGAAGACTCCA	2	AATCTACTGGGACGGAACAGCTTTG	1	MINUS	ILLUMINA	1.771	false	
TRADD	NM_003789	6778390	2	1	Homo sapiens	hg19	chr16	67190445	67189518	CAGTGTACAGGGCTCTGCAGGCT	9	CGGACGTGCTGCAGATGCTGAAGAT	2	MINUS	ILLUMINA	1.391	false	
TRAF2	NM_021138	6832498	1	2	Homo sapiens	hg19	chr9	139793348	139794078	GTACTGCTCCTTCTGCCTGGCCAGCAT	2	AGAACTGTGCTGCCTGTGTTCA	28	PLUS	ILLUMINA	1.338	false	
TRAF3	NM_145725	6683542	10	11	Homo sapiens	hg19	chr14	103369738	103371586	GAGCGCGGGGCAAGTGGCTCGGAACA	1	AGCTGAGCCGGCATGACCAGAT	4	PLUS	ILLUMINA	1.108	false	
TRAF6	NM_145803	6604754	4	3	Homo sapiens	hg19	chr11	36520072	36518776	TGTTTGCACAAGATGGAACTGAGAC	2	ATTGTGAGTTTGCTCTTATGGATTGTCC	2	MINUS	ILLUMINA	1.861	false	
VCAM1	NM_001199834	6857151	0	1	Homo sapiens	hg19	chr1	101185446	101186075	AGCCTCAAATATACTTTGGATAATGTTTGC	1	GACCACCCCAGAATCTAGATATCTT	1	PLUS	ILLUMINA	1.631	false	
XIAP	NM_001204401	6801488	5	6	Homo sapiens	hg19	chrX	123034514	123040865	ATGAGTCAAGTCAGACTTCATTACAGA	3	ATTAGTACTGAAGAGCAGCTAAGGCG	3	PLUS	ILLUMINA	1.951	false	
[Targets]
Gene Name	Transcript ID	Assay ID	Assay Position	Validated	Left Exon	Right Exon	Probe Strand	Target Sequence
AKT1	NM_001014432	6694989	CENTER	false	4	3	MINUS	CTCCGTCTTCATCAGCTGGCACTGCGCCACAGAGAAGTTGTTGAGGGGAGCCTCAC
ATF1	NM_005171	6832570	CENTER	false	2	3	PLUS	TTCTGCCCCGTGTATCTTCAGAAGATAAGTCTTTCAAAATTTTTCTGTAAGATGGGCGCCGTGCTAGGATCCCGT
BCL10	NM_003921	6712588	FIVE_PRIME	false	1	0	MINUS	CACAGGTATACACGTAAATTTTCTAAGGCGTCCTTCTTCACTTCAGTGAGGTCCT
BCL2L1	NM_138578	6790061	FIVE_PRIME	false	1	0	MINUS	GCCAAGATAAGATTCTGAAGGGAGAGAAAGAGATTCAAATCCGCCTTAGGCAAAGGCAGGCAGGTGCAGCC
BCL3	NM_005178	6793284	NA	false	1	2	PLUS	TACCCTGCACCACAGCAATATGGAGAGGCGTGTCTCCGTCCTCATCTGCACGGGTGG
BIRC2	NM_001166	6703614	CENTER	false	3	4	PLUS	CTCCAGTGGTATCTGAAGTTGACAACAGCTGTTCAAGAAGATGAGGATATCTACCTTGAAT
BIRC3	NM_182962	6764041	NA	false	5	6	PLUS	TGGTCTTCTCCAGGTTCAAAATGGATAATTGATGACTCTGCATTTTCATCTCCTGGGCTGTCT
C3	NM_000064	6629153	FIVE_PRIME	false	1	0	MINUS	AGCCGCAAGATGTTGGGGGTGATGATAGAGTACATGGGACTCCCCAGAGCCAGGGGGAGGTGGGTTAGTA
CARD11	NM_032415	6647989	NA	false	10	9	MINUS	TGATGTTCGCTTCAGGCTGATGGGGGATTTGGCTCTCTGCAGCTGGATGCCCTTCAGGTTCATCCTGCGCTGG
CASP1	NM_033292	6735042	THREE_PRIME	false	9	8	MINUS	AACCTTTACAGAAGGATCTCTTCACTTCCTGCCCACAGACATTCATACAGTTTCCTT
CASP8	NM_033355	6847575	FIVE_PRIME	false	3	4	PLUS	CCATCTCTATGAAAATATCCAGCAGGTTCATGTCATCATCCAGTTTGCATTTGGAGATTTCCT
CCL11	NM_002986	6804658	THREE_PRIME	false	1	2	PLUS	GATATCCTTGGCCAGTTTGGTCTTGAAGATCACAGCTTTCTGGGGACATTTGCCACTGG
CCL2	NM_002982	6719302	FIVE_PRIME	false	1	2	PLUS	AGATCTCCTTGGCCACAATGGTCTTGAAGATCACAGCTTCTTTGGGACACTTGCTGCTG
CCL22	NM_002990	6796839	FIVE_PRIME	false	0	1	PLUS	ATCACGGCAGCAGACGCTGTCTTCCATGTTGGCGCCGTAGGGGCCTGCCTCAGTTGCTTGAAGCGCCACAG
CCL5	NM_002985	6775348	FIVE_PRIME	false	1	0	MINUS	AAAGCAGCAGGGTGTGGTGTCCGAGGAATATGGGGAGGCAGATGCAGGAGCGCAGAGGGCAGTAGC
CCR5	NM_001100168	6792447	FIVE_PRIME	false	1	2	PLUS	GATTGGACTTGACACTTGATAATCCATCTTGTTCCACCCGGGGAGAGTTTCTTGTAGGGGAACGGATGT
CD27	NM_001242	6816931	FIVE_PRIME	false	0	1	PLUS	CTTTCTATGCTGGTCACAGTCCTTCACGAGGAATGTTCCTGGCTCACACATCTGGCAGCACAGCTTT
CD40	NM_001250	6615876	FIVE_PRIME	false	1	2	PLUS	TCTGTGCAGTCACTCACCAGTTTCTGTCCTGGCTGGCACAAAGAACAGCACTGACTGTT
CD69	NM_001781	6793836	THREE_PRIME	false	4	3	MINUS	TCAGAAAAACACACTTGTCAGACCCTGTAACGTTGAACCAGTTGTTAAATTCTTTGCCATTTGACCACTTCCATG
CD80	NM_005191	6856478	NA	false	2	1	MINUS	TTTCACTTCCTTGGTCACGTGGATAACACCTGAACAGAAGTGAGAAAGACCAGCC
CD83	NM_004233	6670785	THREE_PRIME	false	2	3	PLUS	CTGTATTTCTTAAAAGTCTCTTCTTTACGCTGTGCAGGGCATCCTGTCACTCTCAAGATCACCTTGCCACTTAG
CDKN1A	NM_078467	6677447	FIVE_PRIME	false	2	3	PLUS	AGAAGATCAGCCGGCGTTTGGAGTGGTAGAAATCTGTCATGCTGGTCTGCCGCCGTTTTCGACCCTGAGA
CFLAR	NM_003879	6709279	THREE_PRIME	false	3	4	PLUS	ATTCCTGTAACTTGTCCCTGCTCCTTGAACAGACTGCTTGTACTTCTGGATTTTTGTCTTCAGG
CHUK	NM_001278	6652539	THREE_PRIME	false	20	19	MINUS	GTGACAACTCATTCTGTTAACCAACTCCAATCAAGATTCATCATACTATTGCCCTGTTCCTCATTTGCCTC
CSF1	NM_172212	6781994	CENTER	false	3	4	PLUS	TGTCTCATAGAAAGTTCGGACGCAGGCCTTGTCATGCTCTTCATAATCCTTGGTGAAGCAGC
CSF2	NM_000758	6861498	FIVE_PRIME	false	0	1	PLUS	CAAACATTTCTGAGATGACTTCTACTGTTTCATTCATCTCAGCAGCAGTGTCTCTACTCAGGTTCAGGA
CSF3	NM_172219	6783074	FIVE_PRIME	false	0	1	PLUS	ACTGTGCCACAGCAGCAGCTGCAGGGCCATCAGCTTCATGGGGCTCTGGGTGGCAG
CXCL1	NM_001511	6624703	THREE_PRIME	false	2	3	PLUS	TCCCTTCTGGTCAGTTGGATTTGTCACTGTTCAGCATCTTTTCGATGATTTTCTTAACT
CXCL10	NM_001565	6807489	FIVE_PRIME	false	1	0	MINUS	TGATGCAGGTACAGCGTACAGTTCTAGAGAGAGGTACTCCTTGAATGCCACTTAGAGTCAGAAAGATAAGGCAG
CXCL2	NM_002089	6673109	THREE_PRIME	false	3	2	MINUS	CAATAAGCTTCCTCCTTCCTTCTGGTCAGTTGGATTTGCCATTTTTCAGCATCTTTTCGATGATTTTCTTAACC
CXCL9	NM_002416	6724096	FIVE_PRIME	false	1	0	MINUS	CGACCCTTTCTCACTACTGGGGTTCCTTGCACTCCAATCAGAACCAGCAAGATG
EGFR	NM_005228	6606536	FIVE_PRIME	false	0	1	PLUS	AAAAGTGCCCAACTGCGTGAGCTTGTTACTCGTGCCTTGGCAAACTTTCTTTTCCTCCAGAGCCCGACTCGCCGGGCAG
EGR1	NM_001964	6618414	FIVE_PRIME	false	0	1	PLUS	AGCACCTTCTCGTTGTTCAGAGAGATGTCAGGAAAAGACTCTGCGGTCAGGTGCTCGTAGGGCTGCTCGCC
ELK1	NM_001114123	6755908	THREE_PRIME	false	6	5	MINUS	ATGTGCACCTGGGCGCTGCCACTGGATGGAAACTGGAAGGAGAGCTTGGCCGGGCTACGGGGCGCAATGGG
FASLG	NM_000639	6690598	THREE_PRIME	false	2	3	PLUS	AGAGGCATGGACCTTGAGTTGGACTTGCCTGTTAAATGGGCCACTTTCCTCAGCTCC
FOS	NM_005252	6623033	THREE_PRIME	false	2	3	PLUS	GACTTCTCATCTTCTAGTTGGTCTGTCTCCGCTTGGAGTGTATCAGTCAGCTCCCTCCTCCG
GADD45B	NM_015675	6737962	THREE_PRIME	false	2	3	PLUS	TCTTCCAGGCGTCCGTGTGAGGGTTCGTGACCAGGAGACAATGCAGGTCTCGG
HMOX1	NM_002133	6706694	CENTER	false	2	3	PLUS	TTGGTGTCATGGGTCAGCAGCTCCTGCAACTCCTCAAAGAGCTGGATGTTGAGCAGGAACGCAGTCTT
ICAM1	NM_000201	6790055	THREE_PRIME	false	4	5	PLUS	TTTCCCGGACAATCCCTCTCGTCCAGTCGGGGGCCATACAGGACACGAAGCTCCCGGGTCTGGTTCTTGT
IFNA1	NM_024013	6860746	FIVE_PRIME	false	0	0	PLUS	ATTCATCAGGGGAGTTTCTCCCACCCTCTCCTCCTGCATCACACAGGCTTCCAAGTC
IFNB1	NM_002176	6793846	FIVE_PRIME	false	0	0	MINUS	CTCCAGTTTTTCTTCCAGGACTGTCTTCAGATGGTTTATCTGATGATAGACATTAGCCAGGAGGTTCTCAACAATA
IFNG	NM_000619	6757470	FIVE_PRIME	false	1	0	MINUS	AGAGTTCCATTATCCGCTACATCTGAATGACCTGCATTAAAATATTTCTTAAGGTTTTCTGCTTCTTTTACATAT
IKBKE	NM_014002	6823527	FIVE_PRIME	false	0	1	PLUS	TTTCTGTCTGTGGCACGTCCAGGAGCTGAGCCCATCTCCACTGCAGGGGATGCAGGC
IKBKG	NM_003639	6701312	FIVE_PRIME	false	1	2	PLUS	AGAATCTGGTTGCTCTGCCGGATGGCATCTCGGAGCTCTTGATTCTCCTCCAGGCA
IL12B	NM_002187	6841426	NA	false	4	3	MINUS	TCCGCACGTCACCCCTTGGGGGTCAGAAGAGCCTCTGCTGCTTTTGACACTGAATGTCAAATCA
IL15	NM_172175	6718629	THREE_PRIME	false	8	9	PLUS	TCCAGTTCCTCACATTCTTTGCATCCAGATTCTGTTACATTCCCATTAGAAGACAAACTGTTGTTTGCTAGGATGA
IL1B	NM_000576	6710123	FIVE_PRIME	false	1	0	MINUS	TCACTGGCGAGCTCAGGTACTTCTGCCATGGCTGCTTCAGACACTTGAGCAATGAAGATTGGCTGAAGAGAATCCCA
IL1R1	NM_000877	6612632	FIVE_PRIME	false	0	1	PLUS	ACAAATAAGTCTGAGTAACACTTTCATATTCTTCTTGGAGAAGGCCTTGTCTTTTACCAAGGGGTCCA
IL1RN	NM_173843	6641824	THREE_PRIME	false	4	5	PLUS	TCGCTCAGGTCAGTGATGTTAACTGCCTCCAGCTGGAGTCTGGTCTCATCACCAGACTT
IL2	NM_000586	6721451	FIVE_PRIME	false	2	1	MINUS	CTTCTAGACACTGAAGATGTTTCAGTTCTGTGGCCTTCTTGGGCATGTAAAACTTAAATGTGAGCAT
IL6	NM_000600	6820760	FIVE_PRIME	false	0	1	PLUS	AGAAGGCAACTGGACCGAAGGCGCTTGTGGAGAAGGAGTTCATAGCTGGGCTCCT
IL8	NM_000584	6669954	CENTER	false	1	2	PLUS	GAGCTCTCTTCCATCAGAAAGCTTTACAATAATTTCTGTGTTGGCGCAGTGTGGTCCACTCTC
IRAK1	NM_001569	6728992	FIVE_PRIME	false	1	0	MINUS	TCTGGTCGCGCACGATCAGGGCGGCGAACTGGCACCAGTCGGCGGGCTCCAGGG
IRAK2	NM_001570	6803734	CENTER	false	2	3	PLUS	TGGTGGGCTCTGGCTGGAGAGGACCCTGGGCCTGGAAAGGTGGCCATCCTCACAGG
IRF1	NM_002198	6680986	FIVE_PRIME	false	1	0	MINUS	TAGCCAGGGTCTCATGCGCATCCGAGTGATGGGCATGTTGGCTCTGCTGCAGGAGCGATTCGGCGG
LTBR	NM_002342	6732979	FIVE_PRIME	false	2	3	PLUS	TTGTGCAGGGGGCAATCTCCTCGAGGCCCATCACTGGGTCACAGGGGCGGCACAGCTGGCAG
MALT1	NM_006785	6614595	THREE_PRIME	false	15	16	PLUS	TGATAAACATACTGTGAAGACTAGATGTTCCTTTAATTTTTGCAGTGAACTGAGTCTGG
MAP2K6	NM_002758	6649323	FIVE_PRIME	false	0	1	PLUS	CTTCTTTTGGAATTTTAAGGCCAGGGTTTCGCTTCTTGCCTTTCGACTGAGACATTTTCCCCTTTCCTTTGA
MAP3K1	NM_005921	6654353	CENTER	false	1	2	PLUS	CTCCTTTAACTGGGATTGGTTTTACCACCACAGGCCCTCGCCTATTTCTCCTTT
MMP9	NM_004994	6729434	THREE_PRIME	false	11	12	PLUS	CGCCAGTAGAAGCGGTCCTGGCAGAAATAGGCTTTCTCTCGGTACTGGAAGACGTCGTGCGTGTCCAAAGGCAC
MYC	NM_002467	6670402	THREE_PRIME	false	1	2	PLUS	CGATTTCTTCCTCATCTTCTTGTTCCTCCTCAGAGTCGCTGCTGGTGGTGGGCGGTGTCTCCTCA
MYD88	NM_002468	6654261	FIVE_PRIME	false	3	4	PLUS	ATTGCCTTGTACTTGATGGGGATCAGTCGCTTCTGATGGGCACCTGGAGAGAGGCTGAGTGCAAATTTGGTCTGGA
NFKB1	NM_003998	6777413	CENTER	false	5	6	PLUS	CTTTGTCACATGAAGTATACCCAGGTTTGCGAAGCCGACCACCATGTCCTTGGGTCCAGCAGT
NFKB2	NM_002502	6830412	THREE_PRIME	false	19	20	PLUS	AGCTGTATCACCAAGTGACAGTCCCGGCCCTGCTGGGCTGGGCGGGGTCAGGGGTGG
NFKBIA	NM_020529	6810000	THREE_PRIME	false	5	4	MINUS	CTCCAAACACACAGTCATCATAGGGCAGCTCGTCCTCTGTGAACTCCGTGAACTC
NFKBIB	NM_002503	6858306	THREE_PRIME	false	3	4	PLUS	TCCACTGCCAAATGAAGGGGGCTCCGGCCGCACGTGGGCTCCGGTTTGTCAAGGTCAGCTCCAGCATCTC
NFKBIE	NM_004556	6824750	NA	false	3	2	MINUS	GTGGCAATGTGGAGACAAGCCAGACCTTGCCAGTTTTGCAGCTGGAGGTCCAGAGAGT
NR4A2	NM_006186	6729825	THREE_PRIME	false	7	6	MINUS	ACTCTCTTGGGTTCCTTGAGCCCGTGTCTCTCTGTGACCATAGCCAGGGCAGCAATGCAGGA
PDGFB	NM_033016	6816863	CENTER	false	4	3	MINUS	TTCTTAAAGATTGGCTTCTTCCGCACAATCTCGATCTTTCTCACCTGGACAGGTCGCAGCTGCACCTGGGT
PLAU	NM_002658	6845100	CENTER	false	6	7	PLUS	ACCCAGGTAGACGATGTAGTCCTCCTTCTTTGGGTAATCAATGAAGCAGTGTGTGGCGCTGATCACCCAGCAAGG
PTGS2	NM_000963	6636217	THREE_PRIME	false	9	8	MINUS	ACCATAGAGTGCTTCCAACTCTGCAGACATTTCCTTTTCTCCTGTAAGTTCTTCAAATGATTCATAGGGCTTCAGC
RAF1	NM_002880	6850068	THREE_PRIME	false	16	15	MINUS	ATCTTCGGTAGAGAGTGTTGGAGCAGCTCAATGGAAGACAGGATCTGGGGAAAAAGAGGCCTCTCTTCCTTTACT
REL	NM_002908	6858151	THREE_PRIME	false	9	10	PLUS	GCATTTCTCTCACAACTGCATCATGAGAAAACAAGTTTGGTTCTTTTTTGAAGTATCTTCCTTCTCCAATTGAACCG
RELA	NM_001243985	6824561	FIVE_PRIME	false	3	2	MINUS	ACTGTCCCTGGTCCTGTGTAGCCATTGATCTTGATGGTGGGGTGGGTCTTGGTGGTA
RELB	NM_006509	6842556	FIVE_PRIME	false	1	2	PLUS	CCGAAGCCGTTCTCCTTGATGTACTCGTCGATGATCTCTCACCTGTGCTCCTGGAAACGGCGAGCGAGAGT
RHOA	NM_001664	6715927	FIVE_PRIME	false	2	1	MINUS	TCATAATCTTCCTGCCCAGCTGTGTCCCACAAAGCCAACTCTACCTGCTTTCCATCCACCTCGATATCTGCCACATA
RIPK1	NM_003804	6724347	FIVE_PRIME	false	0	1	PLUS	GTCTGTTCATCATCTTCGCCTCCTCCAAGAGGGCCTCGTTGTGCTCAATGCAGTTGGGCCCCTTGTACACTGTTTTCAT
SELE	NM_000450	6752002	THREE_PRIME	false	13	12	MINUS	TGTATCCCTCTAGTTCCCCAGATGCACCTGTTTCTGATTCTTTTGAACTTAAAGGATGTAAGAAGGCT
SELP	NM_003005	6634738	THREE_PRIME	false	16	15	MINUS	CCATGTCTTTGATTCATGGGTGTTTATGGAAACCTTAAGGACTCGGGTCAAATGCAGCGTTTGTAA
SOD2	NM_001024465	6730823	FIVE_PRIME	false	4	3	MINUS	ATCAATCCCCAGCAGTGGAATAAGGCCTGTTGTTCCTTGCAGTGGATCCTGATTTGGAC
STAT1	NM_007315	6644350	THREE_PRIME	false	22	21	MINUS	CCATCAAGTTCCATTGGCTCTGGTGCTTCCTTTGGCCTGGAGTAATACTTTCCAAAGGCA
STAT3	NM_213662	6751980	THREE_PRIME	false	20	19	MINUS	CTGCTGCTTTGTGTATGGTTCCACGGACTGGATCTGGGTCTTACCGCTGATGTCCTTCTCCACCCAAGTGAAAGT
STAT5B	NM_012448	6739147	THREE_PRIME	false	18	17	MINUS	ATCGGTGTCAAGGACTGAGTCAGGGTTCTGTGGGTACATGTTATAGTGAGCCTGGGGACA
TBK1	NM_013254	6713135	THREE_PRIME	false	19	20	PLUS	TCAACGTTGCGAAGGCCACCATCCATGGTTAAAGAGCCAAACCTTTCTAAAATGTGGTTATTTTCAGCAAGTTCTTT
TICAM1	NM_182919	6845614	FIVE_PRIME	false	1	0	MINUS	TGTTCCAGGTTCTGCAGGAGCTGCCCAAGCAGATCAGGGATCCGGGGCTGCCGGCTGCGCCACTGGGTC
TLR1	NM_003263	6764733	FIVE_PRIME	false	3	2	MINUS	GCTGTTCTTCAGATCATCTTGATACAGATACAGATTCCTTTTGTAGGGGTGCCCAATATGCCTTTGTTA
TLR2	NM_003264	6843277	THREE_PRIME	false	1	2	PLUS	GTATGTGGCATTGTCCAGTGCTTCAACCCACAACTACCAGTTGAAAGCAGTGAAAGAGCAAT
TLR3	NM_003265	6619667	THREE_PRIME	false	3	4	PLUS	TTGTTCAATAGCTTGTTGAACTGCATGATGTACCTTGAATCTTTTGCATAATGGGTCTTTTAATAGATGGTGT
TLR6	NM_006068	6648116	FIVE_PRIME	false	1	0	MINUS	AGGGTTGTTCTTCTTCAGAGCATCTTGATATGAGTCCAAATTCAAGATCTCTTTTTCAGAAGAAGAGAAAATAACTT
TLR9	NM_017442	6694397	FIVE_PRIME	false	1	0	MINUS	AGGAGAGACAGCGGGTGCAGGGCGCTGCGGCAGAAACCCATGCTGGGGGGCAGGGGCTTCTCCAGAGGGTCTGGC
TNF	NM_000594	6633875	FIVE_PRIME	false	1	2	PLUS	TTGTCACTCGGGGTTCGAGAAGATGATCTGACTGCCTGGGCCAGAGGGCTGATTAGAGAGAGG
TNFAIP3	NM_006290	6803532	THREE_PRIME	false	7	8	PLUS	ACATCTCTGCGCTGGCTCGATCTCAGTTGCTCTTCTGTCCTTTTGGCCTCATGAAA
TNFRSF10A	NM_003844	6766718	CENTER	false	3	2	MINUS	TGTGTTCCTGGTCGTGGTGCAGGGACTTCTCTCTTCTTCATCTGATTTACAAGCTGTACATGGGAGGCAAGCAA
TNFRSF10B	NM_147187	6691449	NA	false	8	7	MINUS	AGCAGCCTCCTCCTCTGAGACCTTTCAGCTTCTGCCGGTTCCAGCAGATGCTCTGACTCCCCGGGGGACAACAT
TNFRSF1A	NM_001065	6670733	FIVE_PRIME	false	1	0	MINUS	TATATTCCCACCAACAGCTCCAGGAGCACCAGTGGCAGCAGCAGGTCAGGCACGGTGGAG
TNFRSF1B	NM_001066	6623911	FIVE_PRIME	false	2	3	PLUS	TTCTGTTCCCGAGTGCAGGCTTGAGTTTCCACCTGGTCAGAGCTACAGCGGGAGCCACAGCTCAAGCA
TNFSF10	NM_003810	6647296	FIVE_PRIME	false	4	3	MINUS	CCCAGAGCCTTTTCATTCTTGGAGTTTGGAGAAGACAATGTGTTGCTTCTTCCTCTGGTC
TNFSF14	NM_172014	6825972	THREE_PRIME	false	4	3	MINUS	CCGGTCAAGCTGGAGTTGGCCCCTGTGAGATGCGCTGCTGGGTTGACC
TP53	NM_001126114	6709182	THREE_PRIME	false	7	6	MINUS	CAAAGCTGTTCCGTCCCAGTAGATTACCACTGGAGTCTTCCAGTGTGATGATGGT
TRADD	NM_003789	6778390	FIVE_PRIME	false	2	1	MINUS	ATCTTCAGCATCTGCAGCACGTCCGGGCTCCCGCCGCTCTCTGCCAAGGCAGCCTGCAGAGCCCTGTACACTG
TRAF2	NM_021138	6832498	FIVE_PRIME	false	1	2	PLUS	TGAACACAGGCAGCACAGTTCTGAGGCCCAGAGCTGAGGATGCTGGCCAGGCAGAAGGAGCAGTAC
TRAF3	NM_145725	6683542	THREE_PRIME	false	10	11	PLUS	ATCTGGTCATGCCGGCTCAGCTGGGACTCCAGCAGGCCTGTGTTCCGAGCCACTTGCCCCGCGCTC
TRAF6	NM_145803	6604754	FIVE_PRIME	false	4	3	MINUS	GGACAATCCATAAGAGCAAACTCACAATGTGCTTGATGATCCTCAAGATGTCTCAGTTCCATCTTGTGCAAACA
VCAM1	NM_001199834	6857151	FIVE_PRIME	false	0	1	PLUS	AAGATATCTAGATTCTGGGGTGGTCTCGATTTTAAAAGCTTGAGAAGCTGCAAACATTATCCAAAGTATATTTGAGGCT
XIAP	NM_001204401	6801488	THREE_PRIME	false	5	6	PLUS	CGCCTTAGCTGCTCTTCAGTACTAATCTCTTTCTGTAATGAAGTCTGACTTGACTCAT
